TestOS za B&R PLC

  • TestOS offers software and service solutions in the field of automation of B&R PLC controllers.

  • Stable and fast program for testing and controlling B&R PLC devices.

  • Intended for use in machine start-up, remote control, automatic testing and daily use by PLC programmers and users who need to control PLC machines.

  • The user-friendly interface enables easy monitoring and control of the B&R PLC.

TestOs functions

Connection to PLC

When the user is connected to the PLC IP, the software provides the functions described.

Power control

Uporabnik lahko zažene več možnosti za kontrolo napajanja – topel ponovni zagon, hladen ponovni zagon, ponastavitev, ponovna nastavitev, SYSSWCopy, diagnostika, zagon in NMI.

Control of project variables

S povezanega B&R PLC-ja TestOS na ukaz Read Var prebere vse spremenljivke znotraj projekta (lahko bere vse vrste spremenljivk – številske, nize, polja, strukture… iz globalnih iniz lokalnih modulov. TestOS podpira tudi branje in nadzor spremenljivk iz .c / .cpp, .h / .hpp, .st, .ab in drugih). 

Project translation and transfer

The TestOS software enables easy transfer of projects and build options to the B&R PLC. The location of the generated PLC software installation package is copied to the file path. Pressing the Download Project button downloads the project. All changes are displayed in the box below. Compiling the project creates an RUC package and presents the number of errors / warnings from the project in the log.

Automated testing

TestOS can load human-readable scripts and run system tests. When testing the system, we check the input and output feedback. After the system tests are completed, the results are generated. Possible test results include pass, fail, and pass. The duration of each step is shown in the results.

Automatic testing

TestOS can load human-readable scripts and run system tests.

In scripts, we report inputs, outputs and delays with keywords. 

When testing the system, we check the feedback from the inputs and outputs. After the system tests are completed, the results are generated. Possible test results are pass, fail, and pass. 

The duration of each step is shown in the results.

In summary, TestOS is a software for all users of B&R PLC controllers that allows easy access and control of the PLC. 

Without the need to open projects in Automation Studio, the programming environment can limit the user rights and control of the project on the user side, and the user who needs full rights, the environment can also provide full control over the B&R controller.